M12, female, angled, 4 poles, M12, male, angled, 4 poles, rail approved
Product description
Product type: Double-ended cordset
Application: Sensor/actuator, Signal transmisison
Item description:
RA-WWAK4.166-5-RA-WWAS4.166/S4502
Item-No.: 8075385
Cable quality: S4502, RADOX®
Inquiry
Stock: Currently out of stock.
Packaging unit: 1 pcs
Minimum quantity: 10 pcs
Quantity: Your entry was adjusted according to the minimum quantity and packaging unit. pcs
Certifications
Product details
Technical data | A-Side | B-Side |
---|---|---|
Coding of | A | A |
Connector | Female, angled, M12 | Male, angled, M12 |
Contact material | Metal, CuZn, gold-plated | Metal, CuZn, gold-plated |
Contact-carrier material | Plastic, PA, BK | Plastic, PA, BK |
Coupling nut material | Metal, CuZn, nickel-plated | Metal, CuZn, nickel-plated |
Current load (at 40°C) | 4 A | 4 A |
Degree of pollution | 3 | 3 |
Degree of protection (mounted) | IP67 (-30°C...+90°C), IP65 (-40°C...+90°C) | |
Fire prevention according to | DIN EN 45545-2 HL1-3 | |
Grip body material | Plastic, TPU, BK | Plastic, TPU, BK |
Insulation resistance |
|
|
Mechanical life-cycle | >100 mating cycles | >100 mating cycles |
Number of pins | 4 | 4 |
Pin assignment |
|
|
Rated voltage |
|
|
Resistance | 5 mΩ | 5 mΩ |
Sealing (female) material | FPM/FKM | |
Shock & vibration | Class 1, Category B (DIN EN 61373) | |
Standards | IEC 61076-2-101 | IEC 61076-2-101 |
Temperature range | Tx (-40°C...+90°C) |
Halogen-free, electron-beam cross-linked cable with improved behaviour in case of fire, easy to strip, soldering resistant and flexible. The cable is intended for fixed, mechanically protected installation inside railway vehicles or for installation in applications where limited alternating bending stresses occur during operation. The cable fullfills the requirements according to EN 50306-4 and EN 45545-2 (HL1 - HL3). It is characterized by a wide temperature range and a high oil- and fuel resistance. RADOX® is a registered trademark of HUBER+SUHNER AG, Switzerland.
Technical data | |
---|---|
Bending radius (fixed) | 3xØ-cable |
Bending radius (repeated) | 4xØ-cable |
Cable quality | S4502, RADOX® |
Cable-jacket material | RADOX® EM 104 |
Fire prevention according to | DIN EN 45545-2 HL1-3, DIN 5510 fire prevention-levels 1-4, NF F16-101 category A1, A2, B |
Halogen-free | Yes |
Jacket color | BK, similar RAL9005 |
Outer diameter of jacket | 5.7 mm |
Special features | Increased thermal load, flame retardant, low emission of smoke, halogen free, oil- and fuel resistant, RoHs compliant |
Temperature range (fixed) | -40°C...+120°C |
Wire colors | WH 1, WH 2, WH 3, WH 4 |
Wire cross-section | 4 x 1 mm² |
Wire insulation material | RADOX® EI 306 |
Wire structure | 19 x 0,26 mm |